Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 14.488
Filter
1.
J Orthop Surg (Hong Kong) ; 32(2): 10225536241251926, 2024.
Article in English | MEDLINE | ID: mdl-38733065

ABSTRACT

AIM: To explore the effects of tibial osteotomy varus angle combined with posterior tibial slope (PTS) on the stress of polyethylene liner in total knee arthroplasty (TKA) by building finite element model (FEM). METHODS: Established the FEM of standard TKA with tibial osteotomy varus angle 0° to 9° were established and divided into 10 groups. Next, each group was created 10 FEMs with 0° to 9° PTS separately. Calculated the stress on polyethylene liner in each group in Abaqus. Finally, the relevancy between tibial osteotomy angle and polyethylene liner stress was statistically analyzed using multiple regression analysis. RESULTS: As the varus angle increased, the area of maximum stress gradually shifted medially on the polyethylene liner. As the PTS increases, the percentage of surface contact forces on the medial and lateral compartmental of the polyethylene liner gradually converge to the same. When the varus angle is between 0° and 3°, the maximum stress of the medial compartmental surfaces of polyethylene liner rises smoothly with the increase of the PTS. When the varus angle is between 4° and 9°, as the increase of the PTS, the maximum stress of polyethylene liner rises first and then falls, forming a trough at PTS 5° and then rises again. Compared to the PTS, the varus angle has a large effect on the maximum stress of the polyethylene liner (p < .001). CONCLUSION: When the varus angle is 0° to 3°, PTS 0° is recommended, which will result in a more equalized stress distribution of the polyethylene liner in TKA.


Subject(s)
Arthroplasty, Replacement, Knee , Finite Element Analysis , Knee Prosthesis , Osteotomy , Polyethylene , Stress, Mechanical , Tibia , Humans , Arthroplasty, Replacement, Knee/methods , Osteotomy/methods , Tibia/surgery , Prosthesis Design
2.
BMJ Open ; 14(5): e077942, 2024 May 07.
Article in English | MEDLINE | ID: mdl-38719321

ABSTRACT

INTRODUCTION: Even when total knee arthroplasty (TKA) is an extended treatment, most patients experience a suboptimal evolution after TKA. The objectives of this study are the following: (1) to determine the effectiveness of two different prosthesis stabilisation systems on the functionality in activities of daily life, and (2) to determine prognostic biomarkers of knee prosthesis function based on radiological information, quantification of cytokines, intra-articular markers and biomechanical functional evaluation to predict successful evolution. METHODS AND ANALYSIS: The PROKnee trial was designed as a randomised controlled patient-blinded trial with two parallel groups that are currently ongoing. The initial recruitment will be 99 patients scheduled for their first TKA, without previous prosthesis interventions in lower limbs, who will be randomly divided into two groups that differed in the stabilisation methodology incorporated in the knee prosthesis: the MEDIAL-pivot group and the CENTRAL-pivot group. The maximum walking speed will be reported as the primary outcome, and the secondary results will be patient-reported questionnaires related to physical status, cognitive and mental state, radiological test, laboratory analysis and biomechanical instrumented functional performance, such as the 6-minute walking test, timed up-and-go test, gait, sit-to-stand, step-over, and ability to step up and down stairs. All the results will be measured 1 week before TKA and at 1.5, 3, 6 and 12 months after surgery. ETHICS AND DISSEMINATION: All procedures were approved by the Ethical Committee for Research with Medicines of the University Clinical Hospital of Valencia on 8 October 2020 (order no. 2020/181). Participants are required to provide informed consent for the study and for the surgical procedure. All the data collected will be treated confidentially since they will be blinded and encrypted. The results from the trial will be published in international peer-reviewed scientific journals, regardless of whether these results are negative or inconclusive. TRIAL REGISTRATION NUMBER: ClinicalTrials.gov Registry (NCT04850300).


Subject(s)
Activities of Daily Living , Arthroplasty, Replacement, Knee , Humans , Arthroplasty, Replacement, Knee/methods , Randomized Controlled Trials as Topic , Knee Prosthesis , Recovery of Function , Female , Male , Follow-Up Studies , Biomechanical Phenomena , Knee Joint/surgery , Knee Joint/physiopathology
3.
PLoS One ; 19(5): e0302885, 2024.
Article in English | MEDLINE | ID: mdl-38739584

ABSTRACT

BACKGROUND: The Vega System® PS (Aesculap AG, Tuttlingen, Germany) is an advanced, third generation fixed implant that aims to mimic natural knee kinematics by optimizing pivotal motion while reducing surface stress. This study evaluated mid-term survival and clinical outcomes, including range of motion (ROM) of the modern posterior stabilized implant in order to analyse whether this biomechanically successful implant reaches good results in situ. METHODS: The first 100 patients to receive the Vega PS System for total knee arthroplasty were invited to take part in this single centre, single surgeon study. Of these, 84 patients were clinically assessed 5-6 years postoperatively. Data which was obtained during this follow-up examination included revision data, range of motion and clinical scores. RESULTS: The 5-year survival rate for exchange of any component was 97.6%, whereby two patients required replacement of the polyethylene gliding surface. Secondary patella resurfacing was performed in 7 patients. Significantly improved results in comparison to the preoperative state could be obtained at the follow-up: KOOS improved from 39.4 to 78.8, SF-12 PCS improved from 32.1 to 42 SF-12 MCS improved from 46 to 53.8 and patella pain improved from 2.7 to 0.3. The mean ROM of the 84 patients after 5 years was 133.1° and mean total KSS was 189.9. DISCUSSION & CONCLUSIONS: This study demonstrates a high survival rate of the Vega PS System® and significant improvements in clinical outcomes 5 years after implantation. The obtained mean ROM indicates that this implant provides good flexibility of the knee joint, allowing a high number of activities. However, due to the rate of secondary patella implantation, routine resurfacing of the patella for all PS TKA cases is highly recommended. CLINICAL TRIALS REGISTRATION: The study was registered at clinicaltrials.gov (NCT02802085).


Subject(s)
Arthroplasty, Replacement, Knee , Knee Prosthesis , Range of Motion, Articular , Humans , Arthroplasty, Replacement, Knee/methods , Female , Male , Aged , Follow-Up Studies , Middle Aged , Knee Joint/surgery , Knee Joint/physiopathology , Aged, 80 and over , Activities of Daily Living , Biomechanical Phenomena , Treatment Outcome , Prosthesis Design
4.
Jt Dis Relat Surg ; 35(2): 299-304, 2024 Mar 21.
Article in English | MEDLINE | ID: mdl-38727108

ABSTRACT

OBJECTIVES: This study aimed to investigate whether adding tissue samples directly into thioglycolate (TG) broth yielded a greater number of anaerobic organisms than freshly sampled tissue in suspected hip and knee prosthetic joint infections (PJIs). PATIENTS AND METHODS: Between January 2017 and December 2020, a total of 90 patients (46 males, 44 females; median age: 71.7 years; range, 50.8 and 87.8 years) who underwent revision hip or knee arthroplasty were included. Intraoperative samples were taken, with five placed in TG broth and five in standard containers (PC) with subsequent aerobic and anaerobic culturing conducted. Demographic and baseline data of the patients were recorded. The primary outcome was positive bacterial growth from a PJI specimen inoculated directly into TG broth at the time of collection or standard PJI specimen processing. Secondary outcomes investigated were the presence of Cutibacterium acnes (C. acnes) and the curative success of revision procedure. RESULTS: A total of 900 samples (450 PC and 450 TG) were taken from 90 revision arthroplasty patients (47 knees and 43 hips). There was no statistically significant difference in the number of positive bacterial growth samples between TG broth and standard processing (p=0.742). This was consistent with subgroup analysis analyzing C. acnes (p=0.666). CONCLUSION: In hip and knee arthroplasty, there is no benefit in substituting or adding TG broth as a culture medium to better identify both general bacterial species and C. acnes infections specifically. However, the use of TG may be useful in confirming a true positive result for infection.


Subject(s)
Arthroplasty, Replacement, Hip , Arthroplasty, Replacement, Knee , Prosthesis-Related Infections , Thioglycolates , Humans , Prosthesis-Related Infections/diagnosis , Prosthesis-Related Infections/microbiology , Prosthesis-Related Infections/drug therapy , Female , Male , Aged , Middle Aged , Aged, 80 and over , Arthroplasty, Replacement, Knee/adverse effects , Arthroplasty, Replacement, Hip/adverse effects , Thioglycolates/pharmacology , Knee Prosthesis/adverse effects , Knee Prosthesis/microbiology , Culture Media/chemistry , Culture Media/pharmacology , Reoperation , Hip Prosthesis/adverse effects , Hip Prosthesis/microbiology , Specimen Handling/methods , Retrospective Studies
5.
Jt Dis Relat Surg ; 35(2): 396-403, 2024 Apr 26.
Article in English | MEDLINE | ID: mdl-38727120

ABSTRACT

OBJECTIVES: This study aimed to compare the functional outcomes of patients undergoing fixed-bearing medial unicompartmental knee arthroplasty (UKA) classified as either varus or neutral based on their postoperative femorotibial angle (FTA), with the goal of evaluating the impact of FTA on functional results. PATIENTS AND METHODS: A total of 38 knees of 35 patients (27 females, 8 males; mean age: 63.6±7.1 years; range, 52 to 75 years) were included in this retrospective study. The data was collected between December 15, 2020, and January 15, 2021. Patients were categorized into two groups based on their postoperative FTA. The neutral group consisted of patients with an FTA range of 5.1° to 7.4°, while the varus group included patients with an FTA range of 0.1° to 4.8°. Knee Outcome Osteoarthritis Score (KOOS), Visual Analog Scale (VAS) scores, sit to stand test results, and six minute walk test data were analyzed. RESULTS: The mean follow-up was 42.0±19.3 months. The postoperative VAS score for the varus group was 0.95±0.99, whereas the neutral group had a VAS score of 2.19±1.83 (p=0.021). The mean KOOS for the varus group was 88.01±7.88, whereas the neutral group had a mean KOOS score of 78.46±13.69 (p=0.006). CONCLUSION: In patients undergoing UKA, mild varus alignment could yield superior early and midterm functional outcomes compared to a neutral femorotibial angle.


Subject(s)
Arthroplasty, Replacement, Knee , Femur , Osteoarthritis, Knee , Humans , Female , Male , Middle Aged , Aged , Retrospective Studies , Osteoarthritis, Knee/surgery , Osteoarthritis, Knee/physiopathology , Femur/surgery , Knee Joint/surgery , Knee Joint/physiopathology , Range of Motion, Articular , Treatment Outcome , Tibia/surgery , Knee Prosthesis , Recovery of Function
6.
J Orthop Traumatol ; 25(1): 24, 2024 May 04.
Article in English | MEDLINE | ID: mdl-38704499

ABSTRACT

BACKGROUND: This retrospective medium-term follow-up study compares the outcomes of medial fixed-bearing unicompartmental knee arthroplasty (mUKA) using a cemented metal-backed (MB) or an all-polyethylene (AP) tibial component. MATERIALS AND METHODS: The database of our institution was mined for primary mUKA patients implanted with an MB or an AP tibial component (the MB-UKA and AP-UKA groups, respectively) from 2015 to 2018. We compared patient demographics, patient-reported outcome measures (PROMs), and motion analysis data obtained with the Riablo™ system (CoRehab, Trento, Italy). We conducted propensity-score-matching (PSM) analysis (1:1) using multiple variables. RESULTS: PSM analysis yielded 77 pairs of MB-UKA and AP-UKA patients. At 5 years, the physical component summary (PCS) score was 52.4 ± 8.3 in MB-UKA and 48.2 ± 8.3 in AP-UKA patients (p < 0.001). The Forgotten Joint Score (FJS-12) was 82.9 ± 18.8 in MB-UKAs and 73.4 ± 22.5 in AP-UKAs (p = 0.015). Tibial pain was reported by 7.8% of the MB-UKA and 35.1% of the AP-UKA patients (p < 0.001). Static postural sway was, respectively, 3.9 ± 2.1 cm and 5.4 ± 2.3 (p = 0.0002), and gait symmetry was, respectively, 92.7% ± 3.7 cm and 90.4% ± 5.4 cm (p = 0.006). Patient satisfaction was 9.2 ± 0.8 in the MB-UKA and 8.3 ± 2.0 in the AP-UKA group (p < 0.003). CONCLUSIONS: MB-UKA patients experienced significantly better 5-year static sway and gait symmetry outcomes than AP-UKA patients. Although the PROMs of the two groups overlapped, MB-UKA patients had a lower incidence of tibial pain, better FJS-12 and PCS scores, and were more satisfied.


Subject(s)
Arthroplasty, Replacement, Knee , Knee Prosthesis , Metals , Patient Reported Outcome Measures , Propensity Score , Prosthesis Design , Humans , Retrospective Studies , Male , Female , Arthroplasty, Replacement, Knee/methods , Aged , Follow-Up Studies , Middle Aged , Tibia/surgery , Polyethylene , Treatment Outcome , Osteoarthritis, Knee/surgery
7.
Bull Hosp Jt Dis (2013) ; 82(2): 139-145, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38739662

ABSTRACT

PURPOSE: This study aimed to evaluate implant survivor-ship, complications, and re-operation rates following robotic arm-assisted unicompartmental knee arthroplasty (UKA) at mid-term follow-up. METHODS: Patient satisfaction, clinical outcome, and knee alignment restoration were evaluated. All patients undergo-ing robotic arm-assisted medial UKA during a 2-year period were prospectively enrolled. Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) score, varus-valgus deformity, and knee range of motion were studied pre- and postoperatively. Revisions and surgery-related complications were recorded. RESULTS: Eighty-five patients were included in the study (mean age: 71.2 years). The mean follow-up was 74.7 months. One conversion to total knee arthroplasty was performed due to periprosthetic fracture 4.5 years after initial surgery result-ing in a survivorship rate of 98.8%. Overall satisfaction was excellent; 97.7% of patients were satisfied or very satisfied, while none was dissatisfied or very dissatisfied. WOMAC score in total, as well as in each component, exhibited sig-nificant improvement postoperatively. Additionally, knee alignment in the coronal plane as well as flexion contracture were significantly improved following the procedure. CONCLUSIONS: The outcomes of the present cohort revealed that precise prosthesis implantation through the robotic arm-assisted system in UKA provided excellent overall satisfac-tion rates and clinical outcomes at mid-term follow-up.


Subject(s)
Arthroplasty, Replacement, Knee , Knee Joint , Knee Prosthesis , Patient Satisfaction , Range of Motion, Articular , Robotic Surgical Procedures , Humans , Arthroplasty, Replacement, Knee/methods , Arthroplasty, Replacement, Knee/adverse effects , Arthroplasty, Replacement, Knee/instrumentation , Aged , Female , Male , Robotic Surgical Procedures/methods , Robotic Surgical Procedures/adverse effects , Treatment Outcome , Middle Aged , Patient Satisfaction/statistics & numerical data , Follow-Up Studies , Knee Joint/surgery , Knee Joint/physiopathology , Knee Joint/diagnostic imaging , Osteoarthritis, Knee/surgery , Osteoarthritis, Knee/physiopathology , Reoperation/statistics & numerical data , Aged, 80 and over , Recovery of Function , Prospective Studies , Postoperative Complications/etiology , Time Factors
8.
Acta Ortop Mex ; 38(1): 15-21, 2024.
Article in Spanish | MEDLINE | ID: mdl-38657147

ABSTRACT

INTRODUCTION: reconstruction of large bone defects using modular knee arthroplasty (MKA) presents a significant challenge in terms of functionality. The objective of the present work was to identify the different prognostic factors associated with failure of MKA in cancer patients. MATERIAL AND METHODS: a retrospective cohort study was conducted, including patients with a diagnosis of musculoskeletal tumor in the distal femur or proximal tibia, who underwent MKA between January 1, 2010, and December 31, 2021. RESULTS: 49 patients were included, of which 25 (51.02%) were women and 24 (48.98%) men, with a mean age of 29.57 years. Of these, 14 (28.57%) patients experienced some type of MKA failure. The most frequent complication that led to failure was periprosthetic infection, observed in seven (14.29%) patients. Variables associated with MKA failure included biopsies performed outside our hospital (HR 3.2, 95% CI 1.4-6.4, p = 0.02), the length of the long axis of the tumor (HR 2.1, 95% CI 1.2-4.6, p = 0.01) and a prolonged surgical time (HR 3.37, 95% CI 1.1-8.6, p = 0.04). CONCLUSION: the most significant prognostic factors associated with MKA failure in our cohort were tumor size, prolonged surgical time, and performance of the diagnostic biopsy in a center not specialized in the management of this type of patient. These findings highlight the importance of considering these variables to improve outcomes in patients undergoing MKA.


INTRODUCCIÓN: la reconstrucción de grandes defectos óseos mediante artroplastía modular de rodilla (AMR) representa un desafío significativo en términos de funcionalidad. El objetivo del presente trabajo fue identificar los diferentes factores pronósticos asociados al fracaso de la AMR en pacientes oncológicos. MATERIAL Y MÉTODOS: se realizó un estudio de cohorte retrospectiva, incluyendo pacientes con diagnóstico de tumor musculoesquelético en el fémur distal o la tibia proximal, que fueron sometidos a AMR entre el 1 de Enero de 2010 y el 31 de Diciembre de 2021. RESULTADOS: se incluyeron 49 pacientes, de los cuales 25 (51.02%) eran mujeres y 24 (48.98%) hombres, con una edad media de 29.57 años. De éstos, 14 (28.57%) pacientes experimentaron algún tipo de fracaso de la AMR. La complicación más frecuente que condicionó el fracaso fue la infección periprotésica, observada en siete (14.29%) pacientes. Las variables asociadas con el fracaso de las AMR incluyeron biopsias realizadas fuera de nuestro hospital (HR 3.2, IC95% 1.4-6.4, p = 0.02), longitud del eje mayor del tumor (HR 2.1, IC95% 1.2-4.6, p = 0.01) y tiempo quirúrgico prolongado (HR 3.37, IC95% 1.1-8.6, p = 0.04). CONCLUSIÓN: los factores pronósticos asociados al fracaso de las AMR en nuestra cohorte fueron el tamaño del tumor, un tiempo quirúrgico prolongado y la realización de la biopsia diagnóstica en un centro no especializado en el manejo de este tipo de pacientes. Estos hallazgos resaltan la importancia de considerar estas variables en pacientes sometidos a AMR.


Subject(s)
Arthroplasty, Replacement, Knee , Humans , Male , Female , Retrospective Studies , Arthroplasty, Replacement, Knee/methods , Adult , Prognosis , Middle Aged , Bone Neoplasms/surgery , Young Adult , Prosthesis-Related Infections/etiology , Operative Time , Prosthesis Failure , Tibia/surgery , Adolescent , Knee Prosthesis , Treatment Failure
9.
Arch Orthop Trauma Surg ; 144(5): 1997-2006, 2024 May.
Article in English | MEDLINE | ID: mdl-38570357

ABSTRACT

BACKGROUND: This study aimed to meta-analyze epidemiological data, revision rates, and incidences of different designs of a single Total Knee Arthroplasty System and compare these factors across different countries. METHODS: A systematic review was conducted on clinical studies and arthroplasty registries of ATTUNE TKA from 1999 to 2020. The main endpoints analyzed were revision rates and epidemiological data. RESULTS: The average age of patients was 67.8 years, with a gender distribution of 60% female and 40% male. The pooled average BMI was 29.4 kg/m2. Eight clinical studies showed a pooled revision rate per 100 observed CY of 0.5 (n = 1343 cases). Cumulative revision rates after 1, 3, and 5 years varied among registries, with the Swiss registry having the highest revision data (after 5 years: 6.3%) and the American registry having the lowest revision data (after 5 years: 1.7%). A comparison of the revision rates of mobile bearing and fixed bearing (41,200 cases) as well as cruciate retaining and posterior stabilized (n = 123,361 cases) showed no significant advantage in the first 5 years after implantation. CONCLUSION: In conclusion, pooled data from 41,200 cases of TKA with a single Total Knee Arthroplasty System in two arthroplasty registries revealed that there was no significant difference in revision rates between the mobile bearing and fixed bearing design within the first 5 years after implantation. In addition, a comparison of the revision rates in n = 123,361 cases showed no significant advantage for cruciate retaining or posterior stabilized in the first 5 years after implantation.


Subject(s)
Arthroplasty, Replacement, Knee , Knee Prosthesis , Prosthesis Design , Registries , Reoperation , Humans , Arthroplasty, Replacement, Knee/statistics & numerical data , Arthroplasty, Replacement, Knee/methods , Reoperation/statistics & numerical data , Male , Female , Prosthesis Failure , Clinical Trials as Topic/statistics & numerical data , Aged
10.
Arch Orthop Trauma Surg ; 144(5): 2267-2271, 2024 May.
Article in English | MEDLINE | ID: mdl-38587669

ABSTRACT

The symmetry of the flexion and extension gap influences the functional and long-term outcome after total knee arthroplasty (TKA). Most surgeons check it by applying varus and valgus stress using spacers. This technique has limited accuracy and could be easily extended by rotational movement of the spacer. The objective was to determine the detection threshold and interobserver reliability of this technique. In an in vitro setting with a human cadaveric knee, gap asymmetries were simulated by different medially and laterally applied forces. Using an optical measurement system, the pivot point of the spacer was calculated as a function of the gap symmetry in the first part of the experiment. In the second part, the detection threshold and interobserver reliability of 4 surgeons were determined. For this purpose, gap asymmetries were adjusted to between 0 and 120N in a blinded trial. With a symmetrical gap, the centre of rotation of the spacer was located in the centre of the tibia. With increasing gap asymmetry, the centre of rotation of the spacer shifted to the tight side. This shift was approximately linearly dependent on the force difference. A perfectly balanced gap was detected by the examiners in 50% of the cases. From a force difference of 40N, all examiners identified the gap asymmetry in all cases (ICC = 1.0). The method of spacer rotation described is suitable for reliably detecting gap differences at ≥ 40N, independently of the examiner.


Subject(s)
Arthroplasty, Replacement, Knee , Cadaver , Humans , Arthroplasty, Replacement, Knee/methods , Rotation , Knee Prosthesis , Range of Motion, Articular , Knee Joint/surgery , Knee Joint/physiology , Knee Joint/physiopathology , Biomechanical Phenomena , Observer Variation
11.
Arch Orthop Trauma Surg ; 144(5): 2273-2281, 2024 May.
Article in English | MEDLINE | ID: mdl-38615291

ABSTRACT

INTRODUCTION: Following total knee arthroplasty (TKA), there is a significant decline in periprosthetic bone mineral density (BMD), potentially resulting in complications such as prosthetic loosening, periprosthetic fracture, and influencing the postoperative recovery. The objective of this study was to summarize the factors influencing periprosthetic BMD in TKA from existing studies. METHODS: A comprehensive systematic search was performed in 4 databases: Pubmed, Embase, Web of Science, and Cochrane Library. The last search was carried out on October 12, 2023. We used the keywords ''total knee arthroplasty'', ''bone mineral density'' and each of them combined with ''tibia'' and ''femur'' to identify all relevant articles reporting about potential impact factors influencing the periprosthetic BMD in patients after TKA. RESULTS: Out of 1391 articles, 22 published from 2001 to 2023 were included in this systematic review. Following eligibility screening, six significant categories affecting periprosthetic BMD were recognized: prosthesis type, design of stem, coating, body weight, cement, and peg distance. CONCLUSION: Mobile-bearing prostheses, modular polyethylene design, short stems, cruciform stems, avoidance of bone cement, higher body mass index, titanium nitride coating, and a smaller medial peg distance could potentially benefit periprosthetic BMD. Comprehensive consideration of diverse factors influencing periprosthetic BMD before surgery and collaboration with post-operative drug therapy are essential. TRIAL REGISTRY: The PROSPERO registration number is CRD42023472030.


Subject(s)
Arthroplasty, Replacement, Knee , Bone Density , Knee Prosthesis , Humans , Arthroplasty, Replacement, Knee/methods , Prosthesis Design , Periprosthetic Fractures/etiology , Prosthesis Failure
12.
Arch Orthop Trauma Surg ; 144(5): 2283-2295, 2024 May.
Article in English | MEDLINE | ID: mdl-38625551

ABSTRACT

INTRODUCTION: The rate of revision TKA and thus the use of hinged implants (HI) steadily rises. Aseptic loosening lies on the top of the failure patterns. However, no evidence exists until now based on national scale high-caseloads that analyzes the impact of cemented HI stem-design on aseptic survival rates. METHODS: Data on aseptic HI-revisions with full-cemented tibia-stems were conducted from the German Arthroplasty Registry. Cases were divided in primary HI (PHI) and HI used in revision operations (RHI). Endpoint was a new revision following either a PHI or an RHI. The impact of stem conicity (conical vs. cylindrical), diameter (≤ 13 mm vs. > 13 mm), length (≤ 90 mm vs. > 90 mm) and offset on the 6-Year-Cumulative-Aseptic-Revision-Rate (6Y-CARR) was estimated via Kaplan-Meier curve and compared between groups via Log-Rank-Tests. RESULTS: 3953 PHI and 2032 RHI fulfilled inclusion-criteria. Stem conicity had no impact on 6Y-CARR (p = 0.08 and p = 0.8). Diameter > 13 mm hat an impact on PHI (p = 0.05) with lower 6Y-CARR but not on RHI (p = 0.2). Length > 90 mm showed significantly worst 6Y-CARR in PHI (p = 0.0001) but not in RHI (p = 0.3). Offset-stems showed significantly better 6Y-CARR in PHI (p = 0.04), but not in RHI (p = 0.7). CONCLUSION: There was no significant impact of the cemented tibia-stem conicity on 6Y-CARR, neither in PHI nor in RHI. The effect of length, diameter and offset on the 6Y-CARR observed in the PHI, was not detectable in the more complex RHI-cases reflecting its limited clinical relevance by itself in more multifactorial backgrounds. Therefore, results must be interpreted with caution due to considerable system-effects and different utilization-scenarios.


Subject(s)
Arthroplasty, Replacement, Knee , Knee Prosthesis , Prosthesis Design , Prosthesis Failure , Registries , Reoperation , Humans , Arthroplasty, Replacement, Knee/methods , Arthroplasty, Replacement, Knee/instrumentation , Germany/epidemiology , Reoperation/statistics & numerical data , Male , Aged , Female , Tibia/surgery , Middle Aged , Bone Cements
13.
Arch Orthop Trauma Surg ; 144(5): 2327-2335, 2024 May.
Article in English | MEDLINE | ID: mdl-38653837

ABSTRACT

BACKGROUND: Despite advancements in total knee arthroplasty (TKA), 10-20% of patients remain dissatisfied after surgery. Improved anteroposterior (AP) stability provided by medial pivot (MP) implants may theoretically lead to higher patient satisfaction. METHODS: AP stability and patient-reported outcome measures (PROMs) at one-year postsurgery were compared between patients who underwent TKA with MP- (n = 121), posterior stabilized (PS; n = 53) and rotating platform (RP; n = 57) implants in a double-blind multicentre randomized controlled trial (Dutch Trial Register: NL6856, 21-02-2018). AP stability was assessed at 30°, 60° and 90° of knee flexion using a KT-2000 arthrometer. PROMs were measured preoperative and one-year postsurgery. RESULTS: MP-TKA provided significant better AP stability at early flexion (30°) compared to PS- and RP-TKA (median [IQR]; 1.79 [1.14-2.77] mm vs. 3.31 [2.51-4.08] mm vs. 2.82 [1.80-4.03] mm, p < 0.001). Additionally, MP-TKA provided significant better AP stability at mid-flexion (60°) compared to PS-TKA (1.75 [1.23-2.36] mm vs. 2.14 [1.49-2.83] mm, p = 0.014). PROM improvements were comparable between implant designs. AP laxity of ≥ 4 mm at early flexion was independently of implant design associated with significantly worse Kujala scores. The incidence of ≥ 4 mm AP laxity at any knee angle was however not significantly different between implant designs. CONCLUSION: MP-, PS- and RP-TKA all provide excellent and comparable results. Although MP-TKA provided better AP stability at early flexion compared to PS- and RP-TKA, this was found to be unrelated to improved PROMs in favour of MP-TKA. More studies focusing on early and mid-flexion performance based differences between MP and other TKA designs are required to confirm our findings. Other non-implant related factors may play a more important role in the performance of TKA and are potentially worthwhile examining.


Subject(s)
Arthroplasty, Replacement, Knee , Knee Prosthesis , Patient Reported Outcome Measures , Humans , Arthroplasty, Replacement, Knee/methods , Arthroplasty, Replacement, Knee/instrumentation , Double-Blind Method , Male , Aged , Female , Middle Aged , Range of Motion, Articular , Prosthesis Design , Knee Joint/surgery , Knee Joint/physiopathology , Patient Satisfaction , Joint Instability/surgery , Joint Instability/prevention & control
14.
Rev. esp. cir. ortop. traumatol. (Ed. impr.) ; 68(2): 128-133, Mar-Abr. 2024. tab
Article in Spanish | IBECS | ID: ibc-231891

ABSTRACT

Antecedentes y objetivo: Las escalas de valoración de fragilidad no han sido estandarizadas para la evaluación prequirúrgica de pacientes sometidos a un reemplazo total de rodilla (RTR). El objetivo de este estudio fue comparar la eficacia de la escala de valoración de la Sociedad Americana de Anestesiología (ASA), el índice de comorbilidad de Charlson (ICC) y la escala simple de fragilidad (SSF) en la predicción de complicaciones, estancia hospitalaria, reingresos y mortalidad después del RTR electivo. Materiales y métodos: Estudiamos retrospectivamente a 448 pacientes que se sometieron a un RTR por artrosis en nuestra institución entre 2016 y 2019. Estos se dividieron en 2 grupos: grupo A (263 pacientes <80 años) y grupo B (185 pacientes >80 años). Todos fueron clasificados por escalas ASA, ICC y SSF. Resultados: El ICC fue mayor en el grupo B (mediana: 5 [RI: 4-6] vs. 4 [RI: 3-5]; p<0,001); sin embargo, no se asoció con un mayor número de complicaciones. Al realizar un análisis de regresión logística encontramos, para las complicaciones: OR SSF=0,67; ICC=1,11; ASA 3 y 4=0,89 y edad=1,04; mientras que para los reingresos: OR SSF=2,09; ICC=1,01; ASA 3 y 4=0,79 y edad=1. Conclusiones: Las escalas ICC y SSF demostraron no presentar diferencias a la escala ASA en la predicción de reingresos, complicaciones y estancia hospitalaria. Sin embargo, el SSF parece tener una mejor correlación en la predicción de la readmisión no planificada.(AU)


Background and objective: Frailty scores have not been standardized for the preoperative assessment of patients undergoing total knee replacement (TKR). The aim of this study was to compare the efficacy of the American Society of Anesthesiology (ASA) score, the Charlson comorbidity index (ICC) and the simple frailty score (SSF) in predicting complications, hospital stay, readmissions and mortality after elective TKR. Materials and methods: We retrospectively studied 448 patients who underwent TKR for osteoarthritis at our institution between 2016 and 2019. They were divided into two groups: Group A (263 patients, <80 years) and Group B (185 patients, >80 years).). All were classified by ASA, ICC and SSF scores. Results: The ICC was higher in Group B (median 5 [RI: 4-6] vs. 4 [RI: 3-5]; P<.001); however, it was not associated with a higher number of complications. When performing a logistic regression analysis we found, for complications: OR SSF=0.67, ICC=1.11; ASA 3 & 4=0.89 and age=1.04; while for readmissions: OR SSF=2.09; ICC=1.01; ASA 3 & 4=0.79 and age=1. Conclusions: The ICC and SSF scales showed no differences to the ASA scale in the prediction of readmissions, complications and hospital stay. However, the SSF seems to have a better correlation in predicting unplanned readmission.(AU)


Subject(s)
Humans , Male , Female , Aged, 80 and over , Knee Prosthesis , Knee/surgery , Hip Fractures , Length of Stay , Aged, 80 and over , Arthroplasty, Replacement, Knee
15.
Rev. esp. cir. ortop. traumatol. (Ed. impr.) ; 68(2): T128-T133, Mar-Abr. 2024. tab
Article in English | IBECS | ID: ibc-231892

ABSTRACT

Antecedentes y objetivo: Las escalas de valoración de fragilidad no han sido estandarizadas para la evaluación prequirúrgica de pacientes sometidos a un reemplazo total de rodilla (RTR). El objetivo de este estudio fue comparar la eficacia de la escala de valoración de la Sociedad Americana de Anestesiología (ASA), el índice de comorbilidad de Charlson (ICC) y la escala simple de fragilidad (SSF) en la predicción de complicaciones, estancia hospitalaria, reingresos y mortalidad después del RTR electivo. Materiales y métodos: Estudiamos retrospectivamente a 448 pacientes que se sometieron a un RTR por artrosis en nuestra institución entre 2016 y 2019. Estos se dividieron en 2 grupos: grupo A (263 pacientes <80 años) y grupo B (185 pacientes >80 años). Todos fueron clasificados por escalas ASA, ICC y SSF. Resultados: El ICC fue mayor en el grupo B (mediana: 5 [RI: 4-6] vs. 4 [RI: 3-5]; p<0,001); sin embargo, no se asoció con un mayor número de complicaciones. Al realizar un análisis de regresión logística encontramos, para las complicaciones: OR SSF=0,67; ICC=1,11; ASA 3 y 4=0,89 y edad=1,04; mientras que para los reingresos: OR SSF=2,09; ICC=1,01; ASA 3 y 4=0,79 y edad=1. Conclusiones: Las escalas ICC y SSF demostraron no presentar diferencias a la escala ASA en la predicción de reingresos, complicaciones y estancia hospitalaria. Sin embargo, el SSF parece tener una mejor correlación en la predicción de la readmisión no planificada.(AU)


Background and objective: Frailty scores have not been standardized for the preoperative assessment of patients undergoing total knee replacement (TKR). The aim of this study was to compare the efficacy of the American Society of Anesthesiology (ASA) score, the Charlson comorbidity index (ICC) and the simple frailty score (SSF) in predicting complications, hospital stay, readmissions and mortality after elective TKR. Materials and methods: We retrospectively studied 448 patients who underwent TKR for osteoarthritis at our institution between 2016 and 2019. They were divided into two groups: Group A (263 patients, <80 years) and Group B (185 patients, >80 years).). All were classified by ASA, ICC and SSF scores. Results: The ICC was higher in Group B (median 5 [RI: 4-6] vs. 4 [RI: 3-5]; P<.001); however, it was not associated with a higher number of complications. When performing a logistic regression analysis we found, for complications: OR SSF=0.67, ICC=1.11; ASA 3 & 4=0.89 and age=1.04; while for readmissions: OR SSF=2.09; ICC=1.01; ASA 3 & 4=0.79 and age=1. Conclusions: The ICC and SSF scales showed no differences to the ASA scale in the prediction of readmissions, complications and hospital stay. However, the SSF seems to have a better correlation in predicting unplanned readmission.(AU)


Subject(s)
Humans , Male , Female , Aged, 80 and over , Knee Prosthesis , Knee/surgery , Hip Fractures , Length of Stay , Aged, 80 and over , Arthroplasty, Replacement, Knee
16.
J Orthop Surg (Hong Kong) ; 32(1): 10225536241246326, 2024.
Article in English | MEDLINE | ID: mdl-38652873

ABSTRACT

BACKGROUND: The single-radius design is one of the major total knee arthroplasty (TKA) designs and widely used all over the world. The objective of this study was to compare in vivo kinematics between the anteroposterior (AP) single-radius design with mediolateral (ML) single-radius (Non Restricted Geometry; NRG) and ML dual-radius (Triathlon) during stair activities. METHODS: A total of 21 knees in 18 patients (NRG group: 10 knees in 7 patients, Triathlon group: 11 knees in 11 patients) with a clinically successful posterior stabilized TKA were examined. Under fluoroscopic surveillance, each patient performed stair ascending and descending motions. In vivo kinematics were analyzed using 2D/3D registration technique. The knee flexion angle, rotation angle, varus-valgus angle, AP translation of the femorotibial contact point for both the medial and lateral sides of the knee, and post-cam engagement were evaluated. RESULTS: There were no significant differences between the two groups in rotation angle and AP translation at each flexion angle. Examining the varus-valgus angle, the NRG group showed varus position at an early flexion angle during both stair activities.Post-cam engagement was observed in both groups during both stair activities. The mean flexion angle of engagement in the NRG group, the post of which was located anterior to the Triathlon, was larger than that in the Triathlon group during both stair activities. CONCLUSION: Despite the same AP single-radius TKA, ML single-radius might affect varus motion at an early flexion angle.


Subject(s)
Arthroplasty, Replacement, Knee , Knee Prosthesis , Prosthesis Design , Range of Motion, Articular , Stair Climbing , Humans , Arthroplasty, Replacement, Knee/methods , Biomechanical Phenomena , Aged , Male , Female , Stair Climbing/physiology , Middle Aged , Knee Joint/physiopathology , Knee Joint/surgery , Osteoarthritis, Knee/surgery , Osteoarthritis, Knee/physiopathology , Aged, 80 and over
17.
Acta Orthop Belg ; 90(1): 51-56, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38669649

ABSTRACT

Patient-specific instrumentation (PSI) was introduced to improve post-operative alignment, and consequently the revision rate and clinical results after total knee arthroplasty (TKA). Short- to mid-term data are conflicting regarding these theoretical advantages of PSI. The purpose of this retrospective analysis was to evaluate the survival rate and clinical outcome in PSI TKA 8.4 years after initial surgery. To our knowledge, no other study investigated long-term follow-up of TKA procedures using PSI. From a total cohort of 184 consecutive patients (200 TKA) 136 patients (144 TKA, 72%) were prospectively analysed at a mean follow-up of 8.4 years (±0.4). A survival analysis with all-cause revision of TKA as endpoint was performed. Patient-reported outcome measures (PROMs) were obtained preoperatively and after 1-, 2-, 5-, and 8.4-years of follow-up. Differences between these moments of follow-up were analysed. At final follow-up, 4 TKAs (2%) had undergone revision, all between 2-4 years after primary surgery. Reasons for revision were late infection, aseptic loosening, instability and polyethylene insert breakage. The median score of certain PROMs (WOMAC, VAS, EQ-index, EQ-VAS) decreased compared to previous follow-up scores but were significantly higher than preoperative scores. After 8.4 years of follow-up, no additional revision surgery was performed compared to 5-years postoperatively. Certain PROMs at 8.4-year follow-up decreased compared to earlier moments of follow-up, but all PROMs improved compared to preoperative PROMs.


Subject(s)
Arthroplasty, Replacement, Knee , Knee Prosthesis , Patient Reported Outcome Measures , Prosthesis Failure , Reoperation , Humans , Arthroplasty, Replacement, Knee/instrumentation , Arthroplasty, Replacement, Knee/methods , Male , Female , Aged , Reoperation/statistics & numerical data , Follow-Up Studies , Prospective Studies , Middle Aged , Retrospective Studies , Treatment Outcome , Aged, 80 and over
18.
BMC Musculoskelet Disord ; 25(1): 277, 2024 Apr 10.
Article in English | MEDLINE | ID: mdl-38600536

ABSTRACT

INTRODUCTION: The number of primary and revision Total Knee Arthroplasty (TKA) cases are expected to increase in future. There are various advantages and disadvantage to employing either of the two main types of stem fixation methods - cemented or hybrid technique. This review aimed to study the most optimal fixation method for revision TKAs by comparing radiological outcomes and re-revision rates. METHODS: A systematic review and meta-analysis was performed using PubMed and Cochrane Library from 2010 to identify studies explicitly comparing outcomes between cemented against hybrid fixation revision TKA techniques, with a minimum follow up of at least 24 months. A total of 8 studies was included in this review. Egger's test and visual inspection of the funnel plot did not reveal publication bias. RESULTS: There was no statistically significant difference in radiological failure and loosening (OR 0.79, CI 0.37-1.66, I2 = 29%, p = 0.22), all causes of re-revision (OR 1.03, CI 0.73-1.44, I2 = 0%, p = 0.56) and aseptic revision (OR 0.74, CI 0.27-2.02, I2 = 0%, p = 0.41) between cemented and hybrid techniques. Functional and pain outcomes compared between the two fixation techniques were largely similar across the studies included in this meta-analysis. CONCLUSION: Despite a trend favouring hybrid stems in revision TKA, current evidence revealed that radiological outcomes and re-revision rates are largely similar between cemented and hybrid fixation techniques.


Subject(s)
Arthroplasty, Replacement, Knee , Knee Prosthesis , Humans , Arthroplasty, Replacement, Knee/methods , Bone Cements/therapeutic use , Physical Examination , Prosthesis Design , Prosthesis Failure , Reoperation/methods , Treatment Outcome
19.
BMC Musculoskelet Disord ; 25(1): 336, 2024 Apr 26.
Article in English | MEDLINE | ID: mdl-38671454

ABSTRACT

BACKGROUND: An optimized fit of the tibial component to the resection platform and correct rotational alignment are critical for successful total knee arthroplasty (TKA). However, there remains controversy regarding the superiority of symmetric tibial component versus asymmetric tibial component. The objective of this systematic review and meta-analysis was to evaluate the current evidence for comparing the coverage and rotation of asymmetrical and symmetrical tibial component. METHODS: We searched potentially relevant studies form PubMed, Web of science, Embase, Cochrane Central Register of Controlled Trials (CENTRAL), and China National Knowledge Infrastructure (CNKI), up to 1 March 2023. Data extraction and quality assessment were performed by two independent reviewers. Meta-analysis was conducted using Review Manager 5.4. RESULTS: Sixteen articles were identified. Compared to symmetric tibial component, asymmetric tibial component increased the coverage of the proximal tibial cut surface (MD, -2.87; 95%CI, -3.45 to -2.28; P < 0.00001), improved the prevalence of tibial baseplate underhang (OR, 0.16; 95%CI, 0.07 to 0.33; P < 0.00001) and malrotation (OR, 0.13; 95%CI, 0.02 to 0.90; P = 0.04), and reduced the degree of tibial component rotation (MD, -3.11; 95%CI, -5.76 to -0.47; P = 0.02). But there was no statistical significance for improving tibial baseplate overhang (OR, 0.58; 95%CI, 0.08 to 3.97; P = 0.58). Additionally, no revision had occurred for the two tibial components in the included studies. CONCLUSION: The current evidence shows asymmetric tibial component offer advantages in terms of coverage and rotation compared with symmetric tibial component in TKA.


Subject(s)
Arthroplasty, Replacement, Knee , Knee Joint , Knee Prosthesis , Tibia , Humans , Arthroplasty, Replacement, Knee/methods , Arthroplasty, Replacement, Knee/instrumentation , Tibia/surgery , Knee Joint/surgery , Rotation , Prosthesis Design , Treatment Outcome , Osteoarthritis, Knee/surgery , Range of Motion, Articular
20.
Medicina (Kaunas) ; 60(4)2024 Mar 31.
Article in English | MEDLINE | ID: mdl-38674229

ABSTRACT

Periprosthetic joint infection is a feared complication after the megaprosthetic reconstruction of oncologic and non-oncologic bone defects of including the knee or hip joint. Due to the relative rarity of these procedures, however, optimal management is debatable. Considering the expanding use of megaprostheses in revision arthroplasty and the high revision burden in orthopedic oncology, the risk of PJI is likely to increase over the coming years. In this non-systematic review article, we present and discuss current management options and the associated results focusing on studies from the last 15 years and studies from dedicated centers or study groups. The indication, surgical details and results in controlling infection are presented for debridement, antibiotics, irrigation and retention (DAIR) procedure with an exchange of the modular components, single-stage implant exchange, two-stage exchanges and ablative procedures.


Subject(s)
Debridement , Prosthesis-Related Infections , Humans , Prosthesis-Related Infections/surgery , Debridement/methods , Arthroplasty, Replacement, Hip/adverse effects , Arthroplasty, Replacement, Hip/methods , Anti-Bacterial Agents/therapeutic use , Anti-Bacterial Agents/administration & dosage , Reoperation/methods , Arthroplasty, Replacement, Knee/adverse effects , Arthroplasty, Replacement, Knee/methods , Knee Prosthesis/adverse effects , Hip Prosthesis/adverse effects , Therapeutic Irrigation/methods
SELECTION OF CITATIONS
SEARCH DETAIL
...